Bag icon
Text logo
لوڈ ہو رہا ہے...دھک-دھک
شراویا

ساہتیہ پاٹی
›Biology: From First Questions to the Frontier

اس باب میں

‹ Learning Anatomy Without a Scalpel, and Watching Life OutdoorsGiving Every Cell Its Own Label ›Biology: From First Questions to the Frontier
لکھیں· salemydop.com
لکھیں· salemydop.com
Biology: From First Questions to the Frontier

باب 520باب520

Building a Structure From a Hundred Thousand Blurred Pictures

Part 23 · Chapter 23.28

Advanced (university)

How single-particle cryo-electron microscopy turns extremely noisy projections of randomly oriented molecules into an atomic model, why the grid and the air-water interface are the hardest part, what the contrast transfer function does and why it must be undone, how orientations are found without knowing them, why half-maps and resolution estimates exist, and how the field learned to distrust its own averages.

What you will learn Explain why single-particle analysis needs no crystal. Describe specimen preparation and the damage done at the air-water interface. Explain the contrast transfer function and its correction. Outline how particles are picked, classified and oriented. Explain gold-standard refinement and the Fourier shell correlation criterion. Distinguish genuine heterogeneity from processing artefact. Judge a published map and its model.
Before you start You should know transmission electron microscopy, vitrification, Fourier transforms in outline, and protein structure.

Key terms

single-particle analysis — Determining a structure by averaging images of many separate copies.

projection — A two-dimensional image in which all depth along the beam is superimposed.

air-water interface — The surface of the thin film, where most particles adsorb and may unfold.

preferred orientation — A tendency for particles to adopt the same angle, leaving directions unsampled.

contrast transfer function — The way defocus and aberration modulate contrast across spatial frequencies.

defocus — Deliberate underfocusing used to generate phase contrast.

motion correction — Realigning frames of a movie to remove beam-induced specimen movement.

two-dimensional classification — Grouping similar particle views to clean the dataset and judge quality.

angular assignment — Determining each particle's orientation by comparison with a reference.

gold-standard refinement — Refining two halves of the data independently to avoid overfitting.

Fourier shell correlation — The agreement between two half-maps as a function of spatial frequency.

local resolution — Resolution varying across the map, usually worse at flexible peripheries.

18 میں سے صفحہ 1
​
پچھلا

745 میں سے باب 520

اگلا
سائنس اور تعلیم
باب

0

0

0

0 بار دیکھا گیا

نومبر 5, 2026

745 میں سے باب 520

18 میں سے صفحہ 1

اس باب میں تقریباً 25 منٹ باقی

اس باب میں

‹ Learning Anatomy Without a Scalpel, and Watching Life OutdoorsGiving Every Cell Its Own Label ›Biology: From First Questions to the Frontier

اس صفحے کی اہم اصطلاحات

projection
— A two-dimensional image in which all depth along the beam is superimposed.
air-water interface
— The surface of the thin film, where most particles adsorb and may unfold.
contrast transfer function
— The way defocus and aberration modulate contrast across spatial frequencies.
single-particle analysis
— Determining a structure by averaging images of many separate copies.

© Xtreme Soul · سیل مائی ڈوپ پر پہلی اشاعت: نومبر 5, 2026. تمام حقوق لکھنے والے کے ہیں؛ اجازت کے بغیر نقل نہ کریں۔ نقل شدہ تحریر کی رپورٹ کریں

لکھنے والا

X

Xtreme Soul

تبصرے
​
​
Xtremesoul
پالیسیاںتمام پالیسیاں·ہم سے رابطہ