›Physics: From First Questions to the Frontier

اس باب میں

‹ 17.2 Radiation Therapy Physics17.4 Radiation Protection ›Physics: From First Questions to the Frontier
لکھیں· salemydop.com
لکھیں· salemydop.com
Physics: From First Questions to the Frontier

17.3 Nuclear Medicine Physics

Medical, Health, and Biological Physics

Reader level Undergraduate to graduate

The tracer principle, choosing radionuclides, production in reactors, cyclotrons, and generators, activity and the tiny masses involved, physical, biological, and effective half-lives, the gamma camera and collimators, SPECT, PET physics (annihilation, coincidence, resolution limits, attenuation, quantification), hybrid imaging, internal dosimetry with the MIRD method, effective doses from scans, radionuclide therapy and theranostics, and radiation protection of patients and staff

Before you begin You should know radioactivity and decay modes from Chapter 11.2, radiation interactions from Chapter 11.5, dose units from Chapter 11.6, detectors and scintillators from Chapter 20.3, imaging physics from Chapter 17.1, and accelerators from Chapter 11.13.
Learning goals After studying this chapter, you should be able to explain the tracer principle; list the properties of a good imaging radionuclide; calculate activity, number of atoms, and mass of a radiopharmaceutical; calculate effective half-lives and decay during transport; describe how a technetium-99m generator works; explain how a gamma camera forms images and calculate collimator resolution; describe SPECT; explain PET coincidence detection and calculate its resolution limits from positron range and photon non-collinearity; calculate attenuation along a PET line of response; explain standardized uptake values; use the MIRD formula for absorbed dose; describe radionuclide therapy and theranostics; and apply time, distance, and shielding to protect staff.
9 میں سے صفحہ 1
​
پچھلا

201 میں سے باب 163

اگلا
سائنس اور تعلیم
باب

0

0

0

2 بار دیکھا گیا

اکتوبر 28, 2026

201 میں سے باب 163

9 میں سے صفحہ 1

اس باب میں تقریباً 14 منٹ باقی

اس باب میں

‹ 17.2 Radiation Therapy Physics17.4 Radiation Protection ›Physics: From First Questions to the Frontier

اس صفحے کی اہم اصطلاحات

Collimator
a lead plate with holes that lets only gamma rays travelling in chosen directions reach a detector.
Theranostics
using the same targeting molecule, labelled with different radionuclides, for diagnosis and therapy.
Radiopharmaceutical
a radioactive compound that follows a biological pathway and is used for imaging or therapy.
Line of response
the line joining two detectors that record coincident annihilation photons in PET.