Detecting Molecules, and Believing the Answer

Part 20 · Chapter 20.10

Intermediate (upper secondary to first-year university)

How biological detection devices are built from a recognition element and a transducer, the glucose sensor and the lateral flow strip as the two devices that reached everyone, the methods for detecting nucleic acids, and the statistics that determine whether a positive result means anything.

What you will learn Describe the two parts of any biosensor and give examples of each. Explain how a lateral flow test works and why it is so cheap. Trace the development of the glucose sensor and explain what each generation changed. Compare PCR, isothermal amplification, CRISPR-based detection and sequencing as ways of finding a sequence. Distinguish sensitivity and specificity from predictive value and calculate predictive value from prevalence. State the ASSURED criteria and explain what each is for.
Before you start You should know antibody structure and antigen binding, enzyme catalysis, nucleic acid base pairing and PCR, and basic probability.

Key terms

biosensor — A device combining a biological recognition element with a transducer that converts recognition into a measurable signal.

recognition element — The component that binds or reacts with the target and determines what is detected.

transducer — The component that converts a recognition event into an electrical, optical or mechanical signal.

immunoassay — An assay using antibodies to detect an analyte.

lateral flow assay — A paper strip test in which capillary flow carries sample past labelled and immobilised antibodies.

sandwich assay — A format in which the analyte is bound by two antibodies at once, giving a signal proportional to analyte.

aptamer — A nucleic acid selected to bind a specific target, used as an alternative to an antibody.

limit of detection — The lowest concentration distinguishable from background with stated confidence.

sensitivity — The proportion of truly positive samples the test calls positive.

specificity — The proportion of truly negative samples the test calls negative.

positive predictive value — The probability that a positive result is correct, which depends on prevalence.

Sayfa 1 / 14
​
Önceki

Bölüm 454 / 745

Sonraki
Bilim ve eğitim
Bölüm

0

0

0

0 görüntülenme

Kas 5, 2026

Bölüm 454 / 745

Sayfa 1 / 14

Bu bölümün bitmesine yaklaşık 20 dk kaldı

Bu bölümde

‹ Building Tissue, and Why Organs Are HarderWho Decides What Gets Built ›Biology: From First Questions to the Frontier

Bu sayfadaki önemli terimler

recognition element
— The component that binds or reacts with the target and determines what is detected.
transducer
— The component that converts a recognition event into an electrical, optical or mechanical signal.
biosensor
— A device combining a biological recognition element with a transducer that converts recognition into a measurable signal.
isothermal amplification
— Nucleic acid amplification at a single temperature, requiring no thermal cycler.