Bag icon
Text logo
Laddar…Dunk-dunk
SHRAVYA

Sahitya Pati
›Biology: From First Questions to the Frontier

I det här kapitlet

‹ Human Epithelial, Connective, Muscle and Neural TissuesIntegrated Exercise Physiology ›Biology: From First Questions to the Frontier
Skriv· salemydop.com
Skriv· salemydop.com
Biology: From First Questions to the Frontier

Kapitel 320Kapitel320

Acid-Base Balance and Buffer Systems

Part 11 · Chapter 11.34

Advanced (university)

Why blood pH is held so narrowly, how buffers, the lungs and the kidneys each defend it on their own timescale, the four primary disturbances and how compensation distinguishes them, and how to read an arterial blood gas result.

What you will learn Explain why pH must be tightly regulated and state the normal range. Describe the bicarbonate buffer system and explain why an open system buffers better than a closed one. Apply the Henderson-Hasselbalch relation. Distinguish the respiratory and renal contributions and their timescales. Describe renal acid excretion including ammonium and titratable acid. Classify the four primary disorders, recognise compensation, and calculate and interpret an anion gap.
Before you start Chapters 11.19 and 11.20 described respiratory and renal physiology separately. This chapter is where they meet, because the two organs together regulate a single variable.

Key terms

pH — The negative logarithm of hydrogen ion concentration; a fall of one unit means a tenfold rise in acidity.

buffer — A mixture of a weak acid and its conjugate base that resists change in pH when acid or base is added.

titratable acid — Acid excreted in the urine bound to buffers such as phosphate, measured by titrating the urine back to plasma pH.

compensation — The secondary change by the other organ system that moves pH back towards normal without correcting the primary fault.

anion gap — The difference between measured cations and measured anions in plasma, used to classify a metabolic acidosis.

base excess — The amount of acid or base that would have to be added to return blood to normal pH at normal carbon dioxide tension.

Why so narrow a range

Arterial blood pH is held between 7.35 and 7.45, a range of hydrogen ion concentration from about 35 to 45 nanomoles per litre. Compare that with sodium at 140 millimoles per litre, a million times more concentrated and regulated far less tightly, and the question becomes why so much machinery is devoted to so little substance.

Sida 1 av 10
​
Föregående

Kapitel 320 av 745

Nästa
Vetenskap och utbildning
Kapitel

0

0

0

0 visningar

nov 5, 2026

Kapitel 320 av 745

Sida 1 av 10

Cirka 15 min kvar av kapitlet

I det här kapitlet

‹ Human Epithelial, Connective, Muscle and Neural TissuesIntegrated Exercise Physiology ›Biology: From First Questions to the Frontier

Nyckelbegrepp på sidan

pH
— The negative logarithm of hydrogen ion concentration; a fall of one unit means a tenfold rise in acidity.
buffer
— A mixture of a weak acid and its conjugate base that resists change in pH when acid or base is added.
compensation
— The secondary change by the other organ system that moves pH back towards normal without correcting the primary fault.
titratable acid
— Acid excreted in the urine bound to buffers such as phosphate, measured by titrating the urine back to plasma pH.

© Xtreme Soul · Först publicerad på salemydop nov 5, 2026. Alla rättigheter tillhör författaren; kopiera inte utan tillstånd. Anmäl kopierat verk

Författare

X

Xtreme Soul

Kommentarer
​
​
Xtremesoul
Villkor och policyerAlla policyer·Kontakta oss