Light, X-rays and Magnets as Ways of Seeing Molecules

Part 23 · Chapter 23.19

Advanced (university)

How absorbance is used to measure concentration and follow a reaction, what circular dichroism reports about protein folding, how X-ray crystallography turns diffraction into a structure, what nuclear magnetic resonance adds for molecules in solution, and how to judge the quality of a published structure.

What you will learn Use absorbance correctly to determine concentration and enzyme rate, and state its limits. Explain what circular dichroism measures and what it can and cannot establish. Describe crystallisation, diffraction and the phase problem, and explain resolution and R factors. Explain chemical shift, coupling and the nuclear Overhauser effect and what each contributes. Choose between crystallography, nuclear magnetic resonance and cryo-electron microscopy for a given problem. Read a structure's validation statistics critically.
Before you start You should know the Beer-Lambert relationship, the levels of protein structure, and that waves interfere.

Key terms

absorbance — The logarithm of the ratio of incident to transmitted light, proportional to concentration.

molar extinction coefficient — The absorbance of a one molar solution over a one centimetre path.

spectrophotometer — An instrument measuring absorbance at chosen wavelengths.

circular dichroism — Difference in absorption of left and right circularly polarised light, abbreviated CD.

diffraction — Interference of waves scattered by a regular array.

unit cell — The repeating box from which a crystal is built.

structure factor — The amplitude and phase of a diffracted beam.

phase problem — The loss of phase information in a diffraction measurement.

electron density map — The three-dimensional map calculated from amplitudes and phases.

resolution of a structure — The finest spacing of diffraction data used, in angstroms.

R factor — A measure of agreement between the model and the observed diffraction.

chemical shift — The resonance frequency of a nucleus relative to a reference, reporting its environment.

nuclear Overhauser effect — Transfer of magnetisation between nuclei close in space, abbreviated NOE.

Pagina 1 van 17
​
Vorige

Hoofdstuk 511 van 745

Volgende
Wetenschap en onderwijs
Hoofdstuk

0

0

0

0 weergaven

nov 5, 2026

Hoofdstuk 511 van 745

Pagina 1 van 17

Nog ongeveer 22 min in dit hoofdstuk

In dit hoofdstuk

‹ Separating a Mixture, Then Weighing What Comes OutReading DNA, From One Gel Lane to Billions of Reads ›Biology: From First Questions to the Frontier

Kernbegrippen op deze pagina

absorbance
— The logarithm of the ratio of incident to transmitted light, proportional to concentration.
circular dichroism
— Difference in absorption of left and right circularly polarised light, abbreviated CD.
diffraction
— Interference of waves scattered by a regular array.
phase problem
— The loss of phase information in a diffraction measurement.

© Xtreme Soul · Voor het eerst gepubliceerd op salemydop op nov 5, 2026. Alle rechten liggen bij de schrijver; kopieer niets zonder toestemming. Gekopieerd werk melden

Schrijver

X

Xtreme Soul

Reacties
​
​
Xtremesoul
Privacy en voorwaardenAlle pagina’s over privacy en voorwaarden·Contact