Bag icon
Text logo
लोड जुयाच्वंगु दु...धक-धक
श्रव्य

साहित्य पाटी
›Biology: From First Questions to the Frontier

थ्व अध्यायय्

‹ Learning Anatomy Without a Scalpel, and Watching Life OutdoorsGiving Every Cell Its Own Label ›Biology: From First Questions to the Frontier
च्वयादिसँ· salemydop.com
च्वयादिसँ· salemydop.com
Biology: From First Questions to the Frontier

परिच्छेद ५२०अध्याय५२०

Building a Structure From a Hundred Thousand Blurred Pictures

Part 23 · Chapter 23.28

Advanced (university)

How single-particle cryo-electron microscopy turns extremely noisy projections of randomly oriented molecules into an atomic model, why the grid and the air-water interface are the hardest part, what the contrast transfer function does and why it must be undone, how orientations are found without knowing them, why half-maps and resolution estimates exist, and how the field learned to distrust its own averages.

What you will learn Explain why single-particle analysis needs no crystal. Describe specimen preparation and the damage done at the air-water interface. Explain the contrast transfer function and its correction. Outline how particles are picked, classified and oriented. Explain gold-standard refinement and the Fourier shell correlation criterion. Distinguish genuine heterogeneity from processing artefact. Judge a published map and its model.
Before you start You should know transmission electron microscopy, vitrification, Fourier transforms in outline, and protein structure.

Key terms

single-particle analysis — Determining a structure by averaging images of many separate copies.

projection — A two-dimensional image in which all depth along the beam is superimposed.

air-water interface — The surface of the thin film, where most particles adsorb and may unfold.

preferred orientation — A tendency for particles to adopt the same angle, leaving directions unsampled.

contrast transfer function — The way defocus and aberration modulate contrast across spatial frequencies.

defocus — Deliberate underfocusing used to generate phase contrast.

motion correction — Realigning frames of a movie to remove beam-induced specimen movement.

two-dimensional classification — Grouping similar particle views to clean the dataset and judge quality.

angular assignment — Determining each particle's orientation by comparison with a reference.

gold-standard refinement — Refining two halves of the data independently to avoid overfitting.

Fourier shell correlation — The agreement between two half-maps as a function of spatial frequency.

local resolution — Resolution varying across the map, usually worse at flexible peripheries.

१८ मध्ये पौ १
​
न्ह्यः

७४५ मध्ये अध्याय ५२०

लिपा
विज्ञान व शिक्षा
अध्याय

०

०

०

० पाः स्वल

कार्तिक १९, २०८३

७४५ मध्ये अध्याय ५२०

१८ मध्ये पौ १

थ्व अध्यायय् करिब २५ मिनेट ल्यं

थ्व अध्यायय्

‹ Learning Anatomy Without a Scalpel, and Watching Life OutdoorsGiving Every Cell Its Own Label ›Biology: From First Questions to the Frontier

थ्व पौया मू खँग्वः

projection
— A two-dimensional image in which all depth along the beam is superimposed.
air-water interface
— The surface of the thin film, where most particles adsorb and may unfold.
contrast transfer function
— The way defocus and aberration modulate contrast across spatial frequencies.
single-particle analysis
— Determining a structure by averaging images of many separate copies.

© Xtreme Soul · salemydopय् न्हापां पिदंगु कार्तिक १९, २०८३. फुक्क अधिकार च्वमियाके दु; अनुमति मकासे कपी मयानादिसँ। कपी यागु ज्या रिपोर्ट यानादिसँ

च्वमि

X

Xtreme Soul

टिप्पणी
​
​
Xtremesoul
नीतिफुक्क नीति·स्वापू तयादिसँ