Bag icon
Text logo
Φόρτωση…Ντουκ-ντουκ
Shravya

Sahitya Pati
›Biology: From First Questions to the Frontier

Σε αυτό το κεφάλαιο

‹ Separating a Mixture, Then Weighing What Comes OutReading DNA, From One Gel Lane to Billions of Reads ›Biology: From First Questions to the Frontier
Γράψε· salemydop.com
Γράψε· salemydop.com
Biology: From First Questions to the Frontier

Κεφάλαιο 511Κεφάλαιο511

Light, X-rays and Magnets as Ways of Seeing Molecules

Part 23 · Chapter 23.19

Advanced (university)

How absorbance is used to measure concentration and follow a reaction, what circular dichroism reports about protein folding, how X-ray crystallography turns diffraction into a structure, what nuclear magnetic resonance adds for molecules in solution, and how to judge the quality of a published structure.

What you will learn Use absorbance correctly to determine concentration and enzyme rate, and state its limits. Explain what circular dichroism measures and what it can and cannot establish. Describe crystallisation, diffraction and the phase problem, and explain resolution and R factors. Explain chemical shift, coupling and the nuclear Overhauser effect and what each contributes. Choose between crystallography, nuclear magnetic resonance and cryo-electron microscopy for a given problem. Read a structure's validation statistics critically.
Before you start You should know the Beer-Lambert relationship, the levels of protein structure, and that waves interfere.

Key terms

absorbance — The logarithm of the ratio of incident to transmitted light, proportional to concentration.

molar extinction coefficient — The absorbance of a one molar solution over a one centimetre path.

spectrophotometer — An instrument measuring absorbance at chosen wavelengths.

circular dichroism — Difference in absorption of left and right circularly polarised light, abbreviated CD.

diffraction — Interference of waves scattered by a regular array.

unit cell — The repeating box from which a crystal is built.

structure factor — The amplitude and phase of a diffracted beam.

phase problem — The loss of phase information in a diffraction measurement.

electron density map — The three-dimensional map calculated from amplitudes and phases.

resolution of a structure — The finest spacing of diffraction data used, in angstroms.

R factor — A measure of agreement between the model and the observed diffraction.

chemical shift — The resonance frequency of a nucleus relative to a reference, reporting its environment.

nuclear Overhauser effect — Transfer of magnetisation between nuclei close in space, abbreviated NOE.

Σελίδα 1 από 17
​
Προηγούμενο

Κεφάλαιο 511 από 745

Επόμενο
Επιστήμη και εκπαίδευση
Κεφάλαιο

0

0

0

0 προβολές

Νοέ 5, 2026

Κεφάλαιο 511 από 745

Σελίδα 1 από 17

Απομένουν περίπου 22 λεπ. σε αυτό το κεφάλαιο

Σε αυτό το κεφάλαιο

‹ Separating a Mixture, Then Weighing What Comes OutReading DNA, From One Gel Lane to Billions of Reads ›Biology: From First Questions to the Frontier

Βασικοί όροι σε αυτή τη σελίδα

absorbance
— The logarithm of the ratio of incident to transmitted light, proportional to concentration.
circular dichroism
— Difference in absorption of left and right circularly polarised light, abbreviated CD.
diffraction
— Interference of waves scattered by a regular array.
phase problem
— The loss of phase information in a diffraction measurement.

© Xtreme Soul · Πρώτη δημοσίευση στο salemydop στις Νοέ 5, 2026. Όλα τα δικαιώματα ανήκουν στον συντάκτη. Μην το αντιγράφεις χωρίς άδεια. Αναφορά αντιγραμμένου έργου