Bag icon
Text logo
ཁ་འབྱེད་བཞིན་པ...ཐིག-ཐུག
Shravya

Sahitya Pati
›Biology: From First Questions to the Frontier

ལེའུ་འདིའི་ནང

‹ Learning Anatomy Without a Scalpel, and Watching Life OutdoorsGiving Every Cell Its Own Label ›Biology: From First Questions to the Frontier
འབྲི· salemydop.com
འབྲི· salemydop.com
Biology: From First Questions to the Frontier

ལེའུ་ 520ལེའུ520

Building a Structure From a Hundred Thousand Blurred Pictures

Part 23 · Chapter 23.28

Advanced (university)

How single-particle cryo-electron microscopy turns extremely noisy projections of randomly oriented molecules into an atomic model, why the grid and the air-water interface are the hardest part, what the contrast transfer function does and why it must be undone, how orientations are found without knowing them, why half-maps and resolution estimates exist, and how the field learned to distrust its own averages.

What you will learn Explain why single-particle analysis needs no crystal. Describe specimen preparation and the damage done at the air-water interface. Explain the contrast transfer function and its correction. Outline how particles are picked, classified and oriented. Explain gold-standard refinement and the Fourier shell correlation criterion. Distinguish genuine heterogeneity from processing artefact. Judge a published map and its model.
Before you start You should know transmission electron microscopy, vitrification, Fourier transforms in outline, and protein structure.

Key terms

single-particle analysis — Determining a structure by averaging images of many separate copies.

projection — A two-dimensional image in which all depth along the beam is superimposed.

air-water interface — The surface of the thin film, where most particles adsorb and may unfold.

preferred orientation — A tendency for particles to adopt the same angle, leaving directions unsampled.

contrast transfer function — The way defocus and aberration modulate contrast across spatial frequencies.

defocus — Deliberate underfocusing used to generate phase contrast.

motion correction — Realigning frames of a movie to remove beam-induced specimen movement.

two-dimensional classification — Grouping similar particle views to clean the dataset and judge quality.

angular assignment — Determining each particle's orientation by comparison with a reference.

gold-standard refinement — Refining two halves of the data independently to avoid overfitting.

Fourier shell correlation — The agreement between two half-maps as a function of spatial frequency.

local resolution — Resolution varying across the map, usually worse at flexible peripheries.

ཤོག་ངོས་ཁྱོན་ 18 ལས་ 1
​
སྔོན་མ

ལེའུ་ཁྱོན་ 745 ལས་ 520

རྗེས་མ
ཚན་རིག་དང་སློབ་གསོ
ལེའུ

0

0

0

ལྟ་ཐེངས་ 0

ཟླ་ 11 5, 2026

ལེའུ་ཁྱོན་ 745 ལས་ 520

ཤོག་ངོས་ཁྱོན་ 18 ལས་ 1

ལེའུ་འདི་ལ་ད་དུང་སྐར་མ་ 25 ཙམ་ལྷག་ཡོད

ལེའུ་འདིའི་ནང

‹ Learning Anatomy Without a Scalpel, and Watching Life OutdoorsGiving Every Cell Its Own Label ›Biology: From First Questions to the Frontier

ཤོག་ངོས་འདིའི་ཐ་སྙད་གལ་ཆེན

projection
— A two-dimensional image in which all depth along the beam is superimposed.
air-water interface
— The surface of the thin film, where most particles adsorb and may unfold.
contrast transfer function
— The way defocus and aberration modulate contrast across spatial frequencies.
single-particle analysis
— Determining a structure by averaging images of many separate copies.

© Xtreme Soul · salemydop ལ་ཐོག་མར་སྤེལ་བའི་ཚེས ཟླ་ 11 5, 2026. དབང་ཆ་ཡོངས་རྫོགས་རྩོམ་པ་པོར་ཡོད། ཆོག་མཆན་མེད་པར་པར་སློག་མ་བྱེད་རོགས། གཞན་ནས་བཤུས་པའི་རྩོམ་ཡིག་སྙན་ཞུ

རྩོམ་པ་པོ

X

Xtreme Soul

བསམ་ཚུལ
​
​
Xtremesoul
སྲིད་ཇུསསྲིད་ཇུས་ཚང་མ·ང་ཚོར་འབྲེལ་བ་གནང